Home
World Journal of Biology Pharmacy and Health Sciences
ISSN Approved | International, Peer reviewed, Referred, Open access Journal

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • WJBPHS CrossMark Policy
    • Publication Ethics
    • Current Issue
    • Issue in Progress
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN Approved Journal | | IMPACT FACTOR 8.16 | | eISSN: 2582-5542 | |  Free Crossref DOI 

Fast Publication within 2 days | | Low Article Processing Charges | | Peer Reviewed and Referred Journal

Research and review articles are invited for publication in September 2026 (Volume 27, Issue 3) Submit Paper

Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200

Breadcrumb

  • Home
  • Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200

Sabrina Belmahi 1, 2, *, Oumaima Nassiri 1, 2, Abdessamad Amrani 1, 2, Amjad Idrissi 1, 2, El-houcine Sebbar 1, 2  and Mohammed Choukri 1, 2

1 Faculty of Medicine and Pharmacy of Oujda, Mohammed First University, Morocco.
2 Central Laboratory, Mohammed VI University Hospital of Oujda, Morocco.

Research Article
 
World Journal of Biology Pharmacy and Health Sciences, 2024, 20(03), 213–219.
Article DOI: 10.30574/wjbphs.2024.20.3.0983
DOI url: https://doi.org/10.30574/wjbphs.2024.20.3.0983

Received on 20 October 2024; revised on 02 December 2024; accepted on 05 December 2024

This study aimed to evaluate the analytical performance of the serum phosphorus assay using the Abbott Architect ci8200® automated system in the biochemistry laboratory of CHU Mohammed VI, Oujda. Method verification was conducted following NF ISO 15189 standards and COFRAC guidelines, assessing key performance parameters such as repeatability, reproducibility, and measurement uncertainty. The colorimetric method for phosphorus determination demonstrated excellent precision, with coefficients of variation (CV) for repeatability ranging from 0.93% to 1.06% across low, medium, and high concentrations. Reproducibility assessments yielded CVs between 2.07% and 2.53%, indicating robust intra-laboratory performance. A comparative analysis between systems using the Bland-Altman method showed strong agreement, with a correlation coefficient of 0.997. Measurement uncertainties at all levels were within acceptable limits. These findings confirm the reliability and accuracy of the assay, highlighting its suitability for clinical diagnostics and its alignment with international accreditation standards.

Iso 15189; Method verification; Phosphorus; Architect ci8200; Quality

https://wjbphs.com/sites/default/files/fulltext_pdf/WJBPHS-2024-0983.pdf

Preview Article PDF

Sabrina Belmahi, Oumaima Nassiri, Abdessamad Amrani, Amjad Idrissi, El-houcine Sebbar and Mohammed Choukri. Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200. World Journal of Biology Pharmacy and Health Sciences, 2024, 20(03), 213–219. Article DOI: https://doi.org/10.30574/wjbphs.2024.20.3.0983

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content


Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


Copyright © 2026 World Journal of Biology Pharmacy and Health Sciences (WJBPHS) - All rights reserved

Developed & Designed by VS Infosolution