Home
World Journal of Biology Pharmacy and Health Sciences
ISSN Approved | International, Peer reviewed, Referred, Open access Journal

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • WJBPHS CrossMark Policy
    • Publication Ethics
    • Current Issue
    • Issue in Progress
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN Approved Journal | | IMPACT FACTOR 8.16 | | eISSN: 2582-5542 | |  Free Crossref DOI 

Fast Publication within 2 days | | Low Article Processing Charges | | Peer Reviewed and Referred Journal

Research and review articles are invited for publication in September 2026 (Volume 27, Issue 3) Submit Paper

Verification of the analytical performance of the serum phosphorus assay on the Abbott Alinity ci®: Experience of the central laboratory Mohammed VI University Hospital of Oujda

Breadcrumb

  • Home
  • Verification of the analytical performance of the serum phosphorus assay on the Abbott Alinity ci®: Experience of the central laboratory Mohammed VI University Hospital of Oujda

Sabah Mokhtari 1, 2, *, Loubna Yacoubi 1, 2, Imane Naji 1, 2, Marouane Kaabouchi 1, 2, NismaDouzi 1, 2, Issam Mokhtari 1, 2, El-houcine Sebbar 1, 2 and Mohammed Choukri 1, 2

1 Central Laboratory, Mohammed VI University Hospital of Oujda, Morocco.
2 Faculty of Medicine and Pharmacy of Oujda, Mohammed First University, Morocco.

Research Article
 
World Journal of Biology Pharmacy and Health Sciences, 2023, 16(01), 233–238.
Article DOI: 10.30574/wjbphs.2023.16.1.0401
DOI url: https://doi.org/10.30574/wjbphs.2023.16.1.0401

Received on 11 August 2023; revised on 26 September 2023; accepted on 28 September 2023

Introduction: In our study, we aimed to evaluate the analytical performance of the serum phosphorus determination method using an Abbott kit on the Alinity c automaton at the biochemistry laboratory of Mohammed VI University Hospital of Oujda.
Materials and methods: We evaluated the performance of the kit using flexible scope A and conducted a thorough performance study on the Alinity c automaton. This study encompassed assessments of repeatability, reproducibility and comparisons of results obtained from two Alinity c automatons.
Results: The obtained results met the acceptability criteria recommended by the supplier and the French Society of Clinical Biology(Société Française de Biologie Clinique SFBC) Valtec protocol, indicating overall satisfaction with the study. The Alinity c automaton exhibited the necessary analytical performance to ensure accurate and dependable determination of phosphorus levels.
Discussion: Ensuring accurate and reliable results, the verification of the serum phosphorus determination method in the medical laboratory is crucial. This process entails implementing quality control measures, calibration, and comparing with established reference methods. It guarantees that the laboratory's phosphorus testing method is precise, accurate, and compliant with industry standards, thereby upholding the quality of patient care.
Conclusion: The verification study of the serum phosphorus determination method yielded satisfactory results, providing high reliability to the test results from the central laboratory at Mohammed VI University Hospital of Oujda. This verification study serves as a strong foundation in the accreditation process, ensuring the accuracy and quality of laboratory testing, and enhancing the overall reliability of patient care

verification; Phosphorus; Quality; Alinity c; ISO 15189

https://wjbphs.com/sites/default/files/fulltext_pdf/WJBPHS-2023-0401.pdf

Get Your e Certificate of Publication using below link

Download Certificate

Preview Article PDF

Sabah Mokhtari, Loubna Yacoubi, Imane Naji, Marouane Kaabouchi, NismaDouzi, Issam Mokhtari, El-houcine Sebbar and Mohammed Choukri. Verification of the analytical performance of the serum phosphorus assay on the Abbott Alinity ci®: Experience of the central laboratory Mohammed VI University Hospital of Oujda. World Journal of Biology Pharmacy and Health Sciences, 2023, 16(01), 233–238. Article DOI: https://doi.org/10.30574/wjbphs.2023.16.1.0401

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content


Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


Copyright © 2026 World Journal of Biology Pharmacy and Health Sciences (WJBPHS) - All rights reserved

Developed & Designed by VS Infosolution